Jordfeilbrytere PFIM/

Then press"OK" and you may select "ACTIVATE". Here in Fig. Figure 6 Begin with the blank screen and your blinking cursor is in the upper left corner. Sjekkliste for UPSHva skal du vite. One obvious application for this would be a to control a flashing warning light. If you see a "STOP" button, the unit is in run mode, and pressing it will stop processing. Marker Relays: These are handy internal relays which can be used as memory or to extend a row if more than 3 contacts are needed such as in the ILLEGAL example shown at the left. Program Menu: To begin programming or to view the circuit diagram, select PROGRAM and press the OK button. But we wanted I2 here, so use the cursor to move one character to the right, to the "1". Multi-Function relay with connection for potentiometer. Uttaksentraler for utebrukEN In cases where severe interference is present, a shielded 2-wire cable should be used. Basic Programming Figure 5 Circuit Diagram: Power the unit up, then press the OK button 3 times and you will arrive at the blank screen where you will enter your program. Terms of service. To reach this screen, go to the status display by pressing ESC several times, then press DEL and ALT at the same time. If a password is set, you cannot view the program. Now move down to the 3rd line, and press OK twice to enter I1. Figure 17 Marker Relays: These are handy internal relays which can be used as memory or to extend a row if more than 3 contacts are needed such as in the ILLEGAL example shown at the left. Caution: any relay coil may appear only once in a circuit diagram. In this circuit diagram Clock 1 contact " 1" controls output relay Q1. Kontaktor 3-pol AxStart Kontakt. See the section on System Menu, below.

Changing unprotected relay function parameters. There are 4 pushbuttons, DEL, ALT, ESC and OK, which are used to program and operate the unit. Tilleggsutstyr - Moeller READ. One obvious application for this would be a to control a flashing warning light. Connecting Transistor Outputs: Figure 44 shows the 24 Volt DC power connections for the outputs, and shows Transistor Output 2 Q2 connected to Load 1, and Transistor Output 3 Q3 connected to Load 2. A momentary activation of the reset coil RT1 will stop the timer.

xPole - PKPM2/PKP62 jordfeilautomater | Eaton

You may not use the latching coil AND the normal coil of the same relay in the same circuit diagram. Figure 5. Connect this resistor between the EASY's input terminal and the N neutral terminal. Wiring for Series DC units is identical. Effektbryter NZM2Komplett effektbry. Figure 3 Program Menu: To begin programming or to view the circuit diagram, select PROGRAM and press the OK button. Figure 29 Figure 30 Figure See below Changing unprotected relay function parameters. This load serves to drain the charge from the sensor when it wants to indicate the "low" state. Kun for sakkyndig oginstruertpersonell! DILMXTEE11 RAC Figure 29 Figure 30 Figure 31 Password Protection: Setting a system password will prevent tampering with the program in the field and will prevent viewing of the program by unauthorized persons. This type of sensor may have difficulty indicating its state to the EASY units, because the EASY units have an extremely small current draw. Analog Comparators: The DC models are able to accept 2 analog volt sensors. More magazines by this user. The OK button is used to select menu functions highlighted by the cursor. DILMXTEY20 RAC Figure 27 Text-Display Variables: The series units are able to display text on the screen as desired, however this can only be entered via EASY-SOFT. Click here to Email the Author Please include your company's name and location. This caution applies to all types of relays, counters, timers, etc.

System Settings Figure 28 The System Screen: This is used to set system defaults and startup behavior. DILMXTEY20 RAC TempoMateriale:ABS, Halogenfri,RoHS. After the reset coil RT1 is deactivated, the timer remains dead until the trigger coil TT1 is momentarily deactivated and then reactivated. Use the up and down cursors to change individual values. Use the OK button to make your selection.

Klockner Moeller EASY Programming Instructions – Control Parts

All series units can remember Marker Relays M13, M14, M15, M16, Timer T7, T8 and Counters C5, C6, C7 and C8 and all 8 Text Relays This feature is useful where a machine must remember it's exact place in a continuing process. Click here to Email the Author Please include your company's name and location. Integrations Wordpress Zapier Dropbox. For Timing Relay Replacement Call NOW! The OK button is used to select menu functions highlighted by the cursor. Figure 4. When the preset time is reached then the timer switches. A total is kept, visible on the parameter screen, and when a preset total is reached, the counter's contacts will switch over. Figure 6. Developer Getting started API SDK. Resources Blog Product changes Videos Magazines. Programming Parameters: Here is a program using a timer. Motorvernbrytere PKZM ,1 - 16 AM. Multi-Function relay with connection for potentiometer. Komplette betj. This has an application in a reversing contactor for example. EMR4-R Insulation Monitoring Relay. This load serves to drain the charge from the sensor when it wants to indicate the "low" state. This way the programmer need not travel to the job-site to make program changes. On-Delay, " X, " : When the TT1 "trigger" coil is activated, the time count begins and the timer's contacts close when the preset time is reached and then remain closed until power is removed from the trigger coil TT1. Main languages.

Figure 20 Clock Controllers " " : Models equipped with a clock can be used to control lighting and other functions on a regular time-of-day and day-of-the-week schedule. Thank you, for helping us keep this platform clean. Figure 39 Figure Enter the symbols shown at left. If you see a "STOP" button, the unit is in run mode, and pressing it will stop processing. Wiring for Series DC units is identical.

Brukerveiledning jordfeilautomat | Hoel Elektro AS

Cart 0. This is a front view of the Moeller EASY programmable controller. Output Relay Q Contacts: Q-Relays have auxiliary contacts which can be used in any of the 3 left columns. The series units also have these additional languages: Portuguese, Dutch, Swedish, Polish and Turkish. After the reset coil RT1 is deactivated, the timer remains dead until the trigger coil TT1 is momentarily deactivated and then reactivated. Eaton Klockner Moeller TIMING RELAYS Image Slider Image Slider Image Slider Image Slider Image Slider Image Slider. Figure 11 Programming Parameters: Here is a program using a timer. This way the programmer need not travel to the job-site to make program changes. This works for any type of contact, timers, counters, clocks, etc. DILMXTED RAC Komplette betj. Connecting Transistor Outputs: Figure 44 shows the 24 Volt DC power connections for the outputs, and shows Transistor Output 2 Q2 connected to Load 1, and Transistor Output 3 Q3 connected to Load 2. If you see a "STOP" button, the unit is in run mode, and pressing it will stop processing. Terms of service. Retention: The units can be set to "retain" or "remember" the value of various functions thru a power-down and resume running exactly where they left off when powered-up again. This caution applies to all types of relays, counters, timers, etc. Figure 3. Figure 3 Program Menu: To begin programming or to view the circuit diagram, select PROGRAM and press the OK button. After you have entered your program, simply hit the ESC button until the Main Menu appears, then select RUN and hit OK. The Card may be plugged in when the unit is powered up. Or, to delete your existing program, select "DELETE PROG" and press the OK button. On-Delay, " X, " : When the TT1 "trigger" coil is activated, the time count begins and the timer's contacts close when the preset time is reached and then remain closed until power is removed from the trigger coil TT1.

Tilleggsutstyr - Moeller READ. Don't wait! A momentary activation of the reset coil RT1 will stop the timer. Notes: A small memory "Card" is available which is used to store the program much in the way one would use a Floppy Disk. A note on AC Inductive Proximity Switches: Certain "inexpensive" proximity switches need to be connected to a load at all times for them to function properly. Figure 17 Marker Relays: These are handy internal relays which can be used as memory or to extend a row if more than 3 contacts are needed such as in the ILLEGAL example shown at the left.

More DILET Info:

Clock Controllers " " : Models equipped with a clock can be used to control lighting and other functions on a regular time-of-day and day-of-the-week schedule. Sjekkliste for UPSHva skal du vite. Tilkoblingsklemmer CuTilkoblingskle. Start using Yumpu now! Main languages. This means that the parameter screen for this particular timer is available even when a password is active, and one may change the time values but not the function or type. Combined with the "Random On-Delay" and "Random Off-Delay" timers shown in the previous section, the lights will come on not at the exact same times each day but rather at somewhat variable times, thereby more closely simulating an occupied house. After the reset coil RT1 is deactivated, the timer remains dead until the trigger coil TT1 is momentarily deactivated and then reactivated. Note that the screen is 4 columns wide, which allows for 3 contacts plus one coil on the right. Note: This screen is not available if a password is set and "active", you must enter the password first and deactivate it. Note, timers are set-up at the contact, not at the coil. But, if I1 were activated, then Jump relay 1 :1 would activate and the entire second line containing I2 would be skipped and the program would continue at the :1 "contact" marker. Figure 35 Startup Mode: The unit can be set to begin running immediately upon power-up, or alternatively to power-up in the "stop" mode, requiring a manual start from the Main Menu. Terms of service. Counter Relays: These are used to count pulses, usually from inputs. Show more documents Share Embed Download Info Flag. When the preset time is elapsed, then timer contact T1 will activate output relay Q1 The "X" in the upper-left corner of the parameter display indicates the type of timer, in this case "on-delay". Figure 43 Connecting Relay Outputs: Figure 43 shows Relay Output Q2 connected to Load 1 and Relay Output Q3 connected to Load 2. EMR4-I Current Monitoring Relay. Figure 10 Fill in any missing "wires" and you're done! Short-link Link Embed. Page 41 and Xpole: Lastbrytere ZP-A EASY DC units can remember Marker Relays M13, M14, M15, M16, Timer T8 and Counter C8.

Figure 39 Figure Timers need parameters set for on-delay or off-delay, time, etc. Here use the up cursor to change the "1" to a "2" and you will have "I2". This is shown in Figure Figure 7. Circuit Diagram: Power the unit up, then press the OK button 3 times and you will arrive at the blank screen where you will enter your program. Use the Program menu selection from the Main Menu to enter your password.